ASC Process Systems Econoclave Autoclave (2011)

Featured Product Details

Location: Van Buren Township, MI

Price: Call

Item Number: 7927

Details

Manufacturer:ASC Process Systems Econoclave
Model:10 x 15-210P800F-24524P48T
Year: 2011
Hours: 1400
Condition: Excellent

Size (Approx.): 120″ Wide
180″ Long
Maximum Working Pressure: 210 PSIG
Maximum Design Pressure of Vessel: 225 PSIG
Pressurization Rate: 10PSI / Minute Average Rate
from 0 to 200 PSIG
Estimated Inlet Flow Rate: 1,256 ft3 / Minute @ 50 PSI Above Set Point Pressure
Depressurization Rate: 10 PSI / Minute Average Rate from 200 PSIG to 0
Steady-State Pressure Control Accuracy: +/- 1.5 PSIG
Temperature: Maximum Working Temperature: 800 Degrees F
Maximum Heating Rate: 10 Degrees F. / Min*
Maximum Cooling Rate: 10 Degrees F / Min
Steady-State Temperature Control Accuracy: +/- 5 Degrees F

Equipped With:
Pressure Vessel with Quick-Opening Breech-Lock Door Certified to ASME Code, Hydraulically Operated Locking Ring & Door Opening & Closing, Side Swing, Inttemal Sheet Metal: Insulation Liner, Aluminized Steel, 18GA, Insulation: Mineral Wool Insulation: 800 Degree F – 6 Degree, Floor Supports: Rail Loading: Capable of 15,000 LBS on a Single Cart, Rail Type: V-Groove or Channel, Fan Circulation System: Air Spped: 200 FPM, Fan Motor: 100-HP / 480V / 3PH / 60Hz, Motor Control: Variable-Speed with Auto-Cutback for Energy Conservation, Motor Mounting: Capsule: Stainless-Steel Cooling Coil, Flow-Switch Indication to PC, Swing-Bolt Capsule Door, Hinged, Pressurization Components: Inlet and Exhaust Valve, 3-Piece Ball Valve, Stainless-Steel Construction, Manual Exhaust Valve, 3-Piece Ball Valve, Stainless-Steel Construction, Exhaust Silencer (Mounted on Autoclave), Pressure Transducer: 1 Accuracy: +/- .25 PSI, Heating Components: Electric Heating Via. Inconel Tubular Heaters: Heaters Mounted Below Floor for Easy System Maintenance, Estimated Heater Size: 440 KW (10 x 15), Multiple Banks with One SCR Bank and Multiple Contactor Control Banks, Proportional Control 0-100% Output

ASC Process Systems Econoclave Model 10 x 15-210P800F-24524P48T Autoclave, Size (Approx.): 120” Wide x 18’ High x 180” Long, Hours: 1400, Maximum Working Pressure: 210 PSIG, Maximum Design Pressure of Vessel: 225 PSIG, Pressurization Rate: 10PSI / Minute Average Rate from 0 to 200 PSIG, Estimated Inlet Flow Rate: 1,256 ft3 / Minute @ 50 PSI Above Set Point Pressure, Depressurization Rate: 10 PSI / Minute Average Rate from 200 PSIG to 0, Steady-State Pressure Control Accuracy: +/- 1.5 PSIG, Temperature: Maximum Working Temperature: 800 Degrees F, Maximum Heating Rate: 10 Degrees F. / Min Based on Average Air Temperature from Ambient to 750 Degree and Autoclave Loaded with 300 LBS Composite, 12,000 LB Steel and 75 Degree Thermal Lag., Maximum Cooling Rate: 10 Degrees F / Min Based on Average Air Temperature from 750 Degree F. to 150 Degree F. and Autoclave Loaded with 30 LBS Composite, 12,000 LBS Steel, and 75 Degree F. Thermal Lag, Steady-State Temperature Control Accuracy: +/- 5 Degrees F., Steady-State Temperature Uniformity within 6” from Walls & Floor: 8 Degrees F. Complete with: Pressure Vessel with Quick-Opening Breech-Lock Door Certified to ASME Code, Hydraulically Operated Locking Ring & Door Opening & Closing, Side Swing, Inttemal Sheet Metal: Insulation Liner, Aluminized Steel, 18GA, Insulation: Mineral Wool Insulation: 800 Degree F – 6 Degree, Floor Supports: Rail Loading: Capable of 15,000 LBS on a Single Cart, Rail Type: V-Groove or Channel, Fan Circulation System: Air Spped: 200 FPM, Fan Motor: 100-HP / 480V / 3PH / 60Hz, Motor Control: Variable-Speed with Auto-Cutback for Energy Conservation, Motor Mounting: Capsule: Stainless-Steel Cooling Coil, Flow-Switch Indication to PC, Swing-Bolt Capsule Door, Hinged, Pressurization Components: Inlet and Exhaust Valve, 3-Piece Ball Valve, Stainless-Steel Construction, Manual Exhaust Valve, 3-Piece Ball Valve, Stainless-Steel Construction, Exhaust Silencer (Mounted on Autoclave), Pressure Transducer: 1 Accuracy: +/- .25 PSI, Heating Components: Electric Heating Via. Inconel Tubular Heaters: Heaters Mounted Below Floor for Easy System Maintenance, Estimated Heater Size: 440 KW (10 x 15), Multiple Banks with One SCR Bank and Multiple Contactor Control Banks, Proportional Control 0-100% Output, S/N: 10501 (2011)

 

 

 

 

 